logo
products
PRODUCTS DETAILS
Home > Products >
L605 Rod Haynes 25 UNS R30605 Chrome Cobalt Alloy Industrial Machinery

L605 Rod Haynes 25 UNS R30605 Chrome Cobalt Alloy Industrial Machinery

MOQ: 150kgs
Price: Negotiatable
Standard Packaging: Wood box for Rod
Delivery Period: 2-30days
Payment Method: ,L/C,T/T,Western Union,MoneyGram
Supply Capacity: 300 Ton per Month
Detail Information
Place of Origin
China
Brand Name
NikTech
Certification
ISO 9001:2008
Model Number
incoloy 800
Thermal Conductivity:
9.4 W/m·K
Melting Point:
1330-1410
Yield Strength:
470–1600 MPa
Tensile Strength:
1130–1900 MPa
Magnetic Properties:
Non-magnetic
Elongation:
30–35%
Hardness:
282 HB
Thermal Expansion:
12.3 μm/m °C (20 – 100°C)
Composition:
Cobalt, Chromium, Tungsten, Nickel, Iron, Molybdenum, Carbon, Silicon, Boron, Phosphorus, Sulfur, And Other Trace Elements
Density:
9.13 G/cm³
Electrical Resistivity:
1.12 μΩ·m
Specific Heat:
377–410 J/kg·K
Elastic Modulus:
210–231 GPa
Highlight:

L605 chrome cobalt alloy

,

R30605 chrome cobalt alloy

,

1600 MPa chromium cobalt

Product Description

High-Performance L605 Rod (Haynes 25/UNS R30605) | Extreme Durability for Demanding Industries


For engineers and buyers across Asia, Russia, and Southeast Asia seeking reliable L605 rod solutions, our cobalt-chromium superalloy (locally called Haynes 25 or Российский аналог L605) delivers unmatched performance in high-temperature and corrosive environments. Optimized for aerospace, energy, and medical applications, L605 rods are engineered to exceed industrial standards.

 


Why Choose L605 Rod?

✅ Superior Heat Resistance – Withstands temperatures up to 1090°C (2000°F) without deformation.
✅ Anti-Corrosion – Resists oxidation, sulfidation, and marine atmospheres.
✅ High Strength-to-Weight Ratio – Ideal for lightweight aerospace components.
✅ Biocompatible – Certified for medical implants (ASTM F90).

 


Chemical Composition of L605 Rod

Element Composition (wt%) Role
Cobalt (Co) 46.4–57% (Balance) Base element, ensures high-temperature stability and toughness
Chromium (Cr) 19–21% Enhances oxidation and corrosion resistance
Tungsten (W) 14–16% Improves creep strength and thermal stability
Nickel (Ni) 9–11% Balances ductility and thermal expansion
Manganese (Mn) 1–2% Aids deoxidation and hot workability
Iron (Fe) ≤3% Controlled to prevent brittleness
Silicon (Si) ≤0.4% Limits harmful phase formation (e.g., Co₂W Laves phase)
Carbon (C) 0.05–0.15% Strengthens via carbide precipitation

 

Physical Properties of L605 Rod

Property Value Conditions
Density 9.13 g/cm³ Room temperature
Melting Range 1330–1410°C (2426–2570°F)  
Thermal Conductivity 9.4 W/m·K 100°C
Specific Heat 385 J/kg·K 21°C
Electrical Resistivity 0.886 μΩ·m Room temperature
Thermal Expansion  7.24in/in x 10-6 93°C
Elastic Modulus 210–231 GPa  

 


Mechanical Properties of L605 Rod

Property Value Conditions
Tensile Strength 1130–1900 MPa Room temperature
Yield Strength 470–1600 MPa Room temperature
Elongation 30–35%  
Hardness (Brinell) 282 HB  
Creep Strength 7000 psi (48 MPa) 980°C (1800°F), 100 hours
Fatigue Strength 260–590 MPa Cyclic loading

 

 


Key Applications of L605 Rod

1. Aerospace & Defense

  • Jet engine combustion liners, turbine seals.

  • Afterburner components (Russia: сопловые аппараты).

2. Oil & Gas

  • Downhole tools for sour gas wells (resists H₂S corrosion).

3. Medical Technology

  • Coronary stents and surgical instruments (ISO 13485 certified).

4. Industrial Machinery

  • High-stress valves, furnace trays in Southeast Asian chemical plants.

  •  

 

Customized L605 Rod Solutions

We supply L605 rods in multiple sizes (Ø5mm–150mm) and finishes (hot-rolled, cold-drawn, polished). Available certifications:

  • AMS 5759 (aerospace)

  • ASTM F90 (medical)

  • GOST standards (Russian clients).

  •  

FAQ: L605 Rod

Q: Can L605 rod be welded?
A: Yes, using TIG or laser welding with Ar shielding. Avoid submerged arc methods.

Q: Is L605 rod magnetic?
A: No – non-magnetic properties suit MRI medical devices.

Q: Delivery time to India or Vietnam?
A: 15–30 days (stocked in Singapore/Malaysia warehouses).

products
PRODUCTS DETAILS
L605 Rod Haynes 25 UNS R30605 Chrome Cobalt Alloy Industrial Machinery
MOQ: 150kgs
Price: Negotiatable
Standard Packaging: Wood box for Rod
Delivery Period: 2-30days
Payment Method: ,L/C,T/T,Western Union,MoneyGram
Supply Capacity: 300 Ton per Month
Detail Information
Place of Origin
China
Brand Name
NikTech
Certification
ISO 9001:2008
Model Number
incoloy 800
Thermal Conductivity:
9.4 W/m·K
Melting Point:
1330-1410
Yield Strength:
470–1600 MPa
Tensile Strength:
1130–1900 MPa
Magnetic Properties:
Non-magnetic
Elongation:
30–35%
Hardness:
282 HB
Thermal Expansion:
12.3 μm/m °C (20 – 100°C)
Composition:
Cobalt, Chromium, Tungsten, Nickel, Iron, Molybdenum, Carbon, Silicon, Boron, Phosphorus, Sulfur, And Other Trace Elements
Density:
9.13 G/cm³
Electrical Resistivity:
1.12 μΩ·m
Specific Heat:
377–410 J/kg·K
Elastic Modulus:
210–231 GPa
Minimum Order Quantity:
150kgs
Price:
Negotiatable
Packaging Details:
Wood box for Rod
Delivery Time:
2-30days
Payment Terms:
,L/C,T/T,Western Union,MoneyGram
Supply Ability:
300 Ton per Month
Highlight

L605 chrome cobalt alloy

,

R30605 chrome cobalt alloy

,

1600 MPa chromium cobalt

Product Description

High-Performance L605 Rod (Haynes 25/UNS R30605) | Extreme Durability for Demanding Industries


For engineers and buyers across Asia, Russia, and Southeast Asia seeking reliable L605 rod solutions, our cobalt-chromium superalloy (locally called Haynes 25 or Российский аналог L605) delivers unmatched performance in high-temperature and corrosive environments. Optimized for aerospace, energy, and medical applications, L605 rods are engineered to exceed industrial standards.

 


Why Choose L605 Rod?

✅ Superior Heat Resistance – Withstands temperatures up to 1090°C (2000°F) without deformation.
✅ Anti-Corrosion – Resists oxidation, sulfidation, and marine atmospheres.
✅ High Strength-to-Weight Ratio – Ideal for lightweight aerospace components.
✅ Biocompatible – Certified for medical implants (ASTM F90).

 


Chemical Composition of L605 Rod

Element Composition (wt%) Role
Cobalt (Co) 46.4–57% (Balance) Base element, ensures high-temperature stability and toughness
Chromium (Cr) 19–21% Enhances oxidation and corrosion resistance
Tungsten (W) 14–16% Improves creep strength and thermal stability
Nickel (Ni) 9–11% Balances ductility and thermal expansion
Manganese (Mn) 1–2% Aids deoxidation and hot workability
Iron (Fe) ≤3% Controlled to prevent brittleness
Silicon (Si) ≤0.4% Limits harmful phase formation (e.g., Co₂W Laves phase)
Carbon (C) 0.05–0.15% Strengthens via carbide precipitation

 

Physical Properties of L605 Rod

Property Value Conditions
Density 9.13 g/cm³ Room temperature
Melting Range 1330–1410°C (2426–2570°F)  
Thermal Conductivity 9.4 W/m·K 100°C
Specific Heat 385 J/kg·K 21°C
Electrical Resistivity 0.886 μΩ·m Room temperature
Thermal Expansion  7.24in/in x 10-6 93°C
Elastic Modulus 210–231 GPa  

 


Mechanical Properties of L605 Rod

Property Value Conditions
Tensile Strength 1130–1900 MPa Room temperature
Yield Strength 470–1600 MPa Room temperature
Elongation 30–35%  
Hardness (Brinell) 282 HB  
Creep Strength 7000 psi (48 MPa) 980°C (1800°F), 100 hours
Fatigue Strength 260–590 MPa Cyclic loading

 

 


Key Applications of L605 Rod

1. Aerospace & Defense

  • Jet engine combustion liners, turbine seals.

  • Afterburner components (Russia: сопловые аппараты).

2. Oil & Gas

  • Downhole tools for sour gas wells (resists H₂S corrosion).

3. Medical Technology

  • Coronary stents and surgical instruments (ISO 13485 certified).

4. Industrial Machinery

  • High-stress valves, furnace trays in Southeast Asian chemical plants.

  •  

 

Customized L605 Rod Solutions

We supply L605 rods in multiple sizes (Ø5mm–150mm) and finishes (hot-rolled, cold-drawn, polished). Available certifications:

  • AMS 5759 (aerospace)

  • ASTM F90 (medical)

  • GOST standards (Russian clients).

  •  

FAQ: L605 Rod

Q: Can L605 rod be welded?
A: Yes, using TIG or laser welding with Ar shielding. Avoid submerged arc methods.

Q: Is L605 rod magnetic?
A: No – non-magnetic properties suit MRI medical devices.

Q: Delivery time to India or Vietnam?
A: 15–30 days (stocked in Singapore/Malaysia warehouses).